The SDM series offers the same protection functions as the SD range and is also designed for international use with two voltage levels:
- Stabilise voltage fluctuations from 88 to 121 VAC or 176 to 242 VAC to within ±1.5 %
- Functional area: 77 until briefly 132 VAC or 154 until briefly 264 VAC
- Attenuates asymmetrical interference voltage spikes from 40 to 60 dB
- Short term voltage dip compensation up to 10 ms
- Input and Output configurable for 110 or 220 VAC
Technical Specifications
Electrical Specifications
| INPUT | SDM 225 | ||
|---|---|---|---|
| Rated input voltage (PRI) | optionally 110 / 220 VAC +10 % … -30 % | ||
| Regulation accuracy at the input voltage | +10 % … -20 % and 100 % load | ||
| Frequency (PRI = SEC) | optionally 50/ 60 Hz (no frequency conversion) | ||
| OUTPUT | SDM 225 | ||
|---|---|---|---|
| Output voltage | optionally 110 /220 VAC sinusoidal | ||
| Output power at 110 / 220 VAC | 200 / 225 VA | ||
| Regulation accuracy (statistical) at Ue ±10 %, IN | ±1.0 % | ||
| Regulation accuracy (statistical) at Ue ±10 % / -20 %, IN | ±1.5 % | ||
| Regulation accuracy (statistical) at Ue ±10 % / 20 %, 0 … IN | +2.5 % / -1.5 % | ||
| Settling time | 20 … 60 ms | ||
| Harmonic content | <5 % under resistive load (Ohm) | ||
| Asymmetric damping (10 … 100 kHZ) | 60 … 40 dB | ||
| ELECTRICAL PROTECTION | SDM 225 | ||
|---|---|---|---|
| Primary fuse (recommended) for 110 / 220 VAC | T 8.0 A / T 4.0 A | ||
| Secondary fuse | only useful for individual partial loads | ||
Mechanical Specifications
| SDM 225 | |||
|---|---|---|---|
| Width | 242 mm | ||
| Height | 216 mm | ||
| Depth | 147 mm | ||
| Weight | 11.0 kg | ||
| Inherent noise | <48 dB (A) | ||
| Mounting | 165 / 66 mm | ||
| Installation method | Floor mounting, wall mounting (horizontal / vertical) | ||
Connection Details
| CONNECTION | SDM 225 | ||
|---|---|---|---|
| Connection type | Input / Output | ||
| Connection technology | Terminal block | ||
Protection and Safety
| PROTECTION AND SAFETY | SDM 225 | ||
|---|---|---|---|
| IP Rating | IP 00 | ||
| Short-circuit-proof | Yes | ||
Environmental Conditions
| SDM 225 | |||
|---|---|---|---|
| Ambient temperature | -25 … +40 °C | ||
| Core temperature | ca. +70 °C | ||
Standards and Regulations
| SDM 225 | |||
|---|---|---|---|
| EU Declaration of Conformity in accordance with | 2011/65/EU, 2014/35/EU | ||
| Standards and regulations | DIN EN IEC 61558-1 DIN EN IEC 61558-2-12 DIN EN IEC 55011 |
||
Commercial Data
| SDM 225 | |||
|---|---|---|---|
| Product group | Magnetic voltage stabilisers | ||
| Packaging unit | 1 item | ||
| Type of packaging | Cardboard box | ||
| Country of origin | DE | ||
| HS Code | 85437090 | ||
| Item number | 13464 | ||
Product Description
Our magnetic voltage stabilisers are robust, durable, stabilise voltage fluctuations, protect against voltage spikes and compensate for voltage dips within milliseconds. For power ratings from 225 to 1350 VA. Reconfigurable at input and output sides to 110 or 220 VAC.
Approvals and Applications

CE Marking
2011/65/EU, 2014/35/EU
Konzept Energietechnik - DC USV Systeme und Stromversorgung